Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 66
Filtrar
1.
Magn Reson Med ; 91(6): 2579-2596, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38192108

RESUMEN

PURPOSE: This study aims to evaluate two distinct approaches for fiber radius estimation using diffusion-relaxation MRI data acquired in biomimetic microfiber phantoms that mimic hollow axons. The methods considered are the spherical mean power-law approach and a T2-based pore size estimation technique. THEORY AND METHODS: A general diffusion-relaxation theoretical model for the spherical mean signal from water molecules within a distribution of cylinders with varying radii was introduced, encompassing the evaluated models as particular cases. Additionally, a new numerical approach was presented for estimating effective radii (i.e., MRI-visible mean radii) from the ground truth radii distributions, not reliant on previous theoretical approximations and adaptable to various acquisition sequences. The ground truth radii were obtained from scanning electron microscope images. RESULTS: Both methods show a linear relationship between effective radii estimated from MRI data and ground-truth radii distributions, although some discrepancies were observed. The spherical mean power-law method overestimated fiber radii. Conversely, the T2-based method exhibited higher sensitivity to smaller fiber radii, but faced limitations in accurately estimating the radius in one particular phantom, possibly because of material-specific relaxation changes. CONCLUSION: The study demonstrates the feasibility of both techniques to predict pore sizes of hollow microfibers. The T2-based technique, unlike the spherical mean power-law method, does not demand ultra-high diffusion gradients, but requires calibration with known radius distributions. This research contributes to the ongoing development and evaluation of neuroimaging techniques for fiber radius estimation, highlights the advantages and limitations of both methods, and provides datasets for reproducible research.


Asunto(s)
Imagen de Difusión por Resonancia Magnética , Modelos Teóricos , Imagen de Difusión por Resonancia Magnética/métodos , Axones , Microscopía , Neuroimagen
2.
Front Neurosci ; 17: 1209521, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37638307

RESUMEN

Axon radius is a potential biomarker for brain diseases and a crucial tissue microstructure parameter that determines the speed of action potentials. Diffusion MRI (dMRI) allows non-invasive estimation of axon radius, but accurately estimating the radius of axons in the human brain is challenging. Most axons in the brain have a radius below one micrometer, which falls below the sensitivity limit of dMRI signals even when using the most advanced human MRI scanners. Therefore, new MRI methods that are sensitive to small axon radii are needed. In this proof-of-concept investigation, we examine whether a surface-based axonal relaxation process could mediate a relationship between intra-axonal T2 and T1 times and inner axon radius, as measured using postmortem histology. A unique in vivo human diffusion-T1-T2 relaxation dataset was acquired on a 3T MRI scanner with ultra-strong diffusion gradients, using a strong diffusion-weighting (i.e., b = 6,000 s/mm2) and multiple inversion and echo times. A second reduced diffusion-T2 dataset was collected at various echo times to evaluate the model further. The intra-axonal relaxation times were estimated by fitting a diffusion-relaxation model to the orientation-averaged spherical mean signals. Our analysis revealed that the proposed surface-based relaxation model effectively explains the relationship between the estimated relaxation times and the histological axon radius measured in various corpus callosum regions. Using these histological values, we developed a novel calibration approach to predict axon radius in other areas of the corpus callosum. Notably, the predicted radii and those determined from histological measurements were in close agreement.

3.
Med Image Anal ; 86: 102767, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-36867913

RESUMEN

We enable the estimation of the per-axon axial diffusivity from single encoding, strongly diffusion-weighted, pulsed gradient spin echo data. Additionally, we improve the estimation of the per-axon radial diffusivity compared to estimates based on spherical averaging. The use of strong diffusion weightings in magnetic resonance imaging (MRI) allows to approximate the signal in white matter as the sum of the contributions from only axons. At the same time, spherical averaging leads to a major simplification of the modeling by removing the need to explicitly account for the unknown distribution of axonal orientations. However, the spherically averaged signal acquired at strong diffusion weightings is not sensitive to the axial diffusivity, which cannot therefore be estimated although needed for modeling axons - especially in the context of multi-compartmental modeling. We introduce a new general method for the estimation of both the axial and radial axonal diffusivities at strong diffusion weightings based on kernel zonal modeling. The method could lead to estimates that are free from partial volume bias with gray matter or other isotropic compartments. The method is tested on publicly available data from the MGH Adult Diffusion Human Connectome project. We report reference values of axonal diffusivities based on 34 subjects, and derive estimates of axonal radii from only two shells. The estimation problem is also addressed from the angle of the required data preprocessing, the presence of biases related to modeling assumptions, current limitations, and future possibilities.


Asunto(s)
Conectoma , Sustancia Blanca , Adulto , Humanos , Imagen de Difusión por Resonancia Magnética/métodos , Sustancia Blanca/diagnóstico por imagen , Axones/patología , Encéfalo/diagnóstico por imagen
5.
Neuroimage ; 258: 119356, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35659995

RESUMEN

Tractography enables identifying and evaluating the healthy and diseased brain's white matter pathways from diffusion-weighted magnetic resonance imaging data. As previous evaluation studies have reported significant false-positive estimation biases, recent microstructure-informed tractography algorithms have been introduced to improve the trade-off between specificity and sensitivity. However, a major limitation for characterizing the performance of these techniques is the lack of ground truth brain data. In this study, we compared the performance of two relevant microstructure-informed tractography methods, SIFT2 and COMMIT, by assessing the subject specificity and reproducibility of their derived white matter pathways. Specifically, twenty healthy young subjects were scanned at eight different time points at two different sites. Subject specificity and reproducibility were evaluated using the whole-brain connectomes and a subset of 29 white matter bundles. Our results indicate that although the raw tractograms are more vulnerable to the presence of false-positive connections, they are highly reproducible, suggesting that the estimation bias is subject-specific. This high reproducibility was preserved when microstructure-informed tractography algorithms were used to filter the raw tractograms. Moreover, the resulting track-density images depicted a more uniform coverage of streamlines throughout the white matter, suggesting that these techniques could increase the biological meaning of the estimated fascicles. Notably, we observed an increased subject specificity by employing connectivity pre-processing techniques to reduce the underlaying noise and the data dimensionality (using principal component analysis), highlighting the importance of these tools for future studies. Finally, no strong bias from the scanner site or time between measurements was found. The largest intraindividual variance originated from the sole repetition of data measurements (inter-run).


Asunto(s)
Conectoma , Sustancia Blanca , Adulto , Imagen de Difusión Tensora , Reacciones Falso Positivas , Femenino , Humanos , Masculino , Reproducibilidad de los Resultados , Sustancia Blanca/anatomía & histología , Sustancia Blanca/diagnóstico por imagen , Sustancia Blanca/fisiología , Adulto Joven
6.
Magn Reson Imaging ; 91: 52-61, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35561868

RESUMEN

This work focuses on obtaining a magnetic resonance imaging (MRI) signal representation that accounts for a longitudinal T1 and transverse T2⋆ relaxations while at the same time integrating directional diffusion in the context of scattered multi-parametric acquisitions, where only a few diffusion gradient directions and b-values are available for each pair of echo and inversion times. The method is based on the three-dimensional simple harmonic oscillator-based reconstruction and estimation (SHORE) representation of the diffusion signal, which enables the estimation of the orientation distribution function and the retrieval of various quantitative indices such as the generalized fractional anisotropy or the return-to-the-origin probability while simultaneously resolving for T1 and T2⋆ relaxation times. Our technique, the Relax-SHORE, has been tested on both in silico and in vivo diffusion-relaxation scattered MR data. The results show that Relax-SHORE is accurate in the context of scattered acquisitions while guaranteeing flexibility in the diffusion signal representation from multi-parametric sequences.


Asunto(s)
Imagen de Difusión por Resonancia Magnética , Imagen por Resonancia Magnética , Anisotropía , Encéfalo , Difusión , Imagen de Difusión por Resonancia Magnética/métodos , Imagen por Resonancia Magnética/métodos
7.
Neuroimage ; 257: 119327, 2022 08 15.
Artículo en Inglés | MEDLINE | ID: mdl-35636227

RESUMEN

Limitations in the accuracy of brain pathways reconstructed by diffusion MRI (dMRI) tractography have received considerable attention. While the technical advances spearheaded by the Human Connectome Project (HCP) led to significant improvements in dMRI data quality, it remains unclear how these data should be analyzed to maximize tractography accuracy. Over a period of two years, we have engaged the dMRI community in the IronTract Challenge, which aims to answer this question by leveraging a unique dataset. Macaque brains that have received both tracer injections and ex vivo dMRI at high spatial and angular resolution allow a comprehensive, quantitative assessment of tractography accuracy on state-of-the-art dMRI acquisition schemes. We find that, when analysis methods are carefully optimized, the HCP scheme can achieve similar accuracy as a more time-consuming, Cartesian-grid scheme. Importantly, we show that simple pre- and post-processing strategies can improve the accuracy and robustness of many tractography methods. Finally, we find that fiber configurations that go beyond crossing (e.g., fanning, branching) are the most challenging for tractography. The IronTract Challenge remains open and we hope that it can serve as a valuable validation tool for both users and developers of dMRI analysis methods.


Asunto(s)
Conectoma , Sustancia Blanca , Encéfalo/diagnóstico por imagen , Conectoma/métodos , Difusión , Imagen de Difusión por Resonancia Magnética/métodos , Imagen de Difusión Tensora/métodos , Humanos , Procesamiento de Imagen Asistido por Computador/métodos
8.
Acta bioquím. clín. latinoam ; 56(1): 3-9, ene. 2022. graf
Artículo en Español | LILACS, BINACIS | ID: biblio-1402941

RESUMEN

Resumen El método de referencia para el estudio bioquímico de la esclerosis múltiple (EM) es el isoelectroenfoque (IEE) y la evaluación de las cadenas livianas libres (CLL) podría brindar una información adicional de relevancia. Por lo tanto, se propone evaluar la presencia de las CLL y la aplicabilidad de los estados de polimerización en el estudio de la EM. Se puso a punto un método compuesto por una separación electroforética en gel de poliacrilamida al 12,5% con posterior electrotransferencia (PAGE-WB) y se realizó la evaluación de 121 pacientes con sospecha de EM en simultáneo al IEE. Los patrones de PAGE-WB relacionados con la EM fueron el aumento de la concentración de monómeros Kappa o dímeros Lambda en líquido cefalorraquídeo (LCR) en comparación con el suero. Este método tuvo una muy alta significación de asociación con el IEE (p<0,0001) con sensibilidad del 95%, especificidad del 90%, VPP 83% y VPN 97%. La síntesis intratecal de CLL quedó evidenciada por el aumento de intensidad del monómero Kappa y/o el dímero Lambda observado en LCR. La técnica de PAGE-WB para CLL demostró ser un método alternativo para detectar la síntesis intratecal en pacientes con sospecha de EM.


Abstract The reference method for the biochemical study of multiple sclerosis (MS) is isoelectric focusing (IEF) and the evaluation of free light chains (FLC) could provide additional information of relevance. Therefore, it is proposed here to evaluate the presence of FLC and the applicability of the polymerisation states in the study of MS. A method consisting of a 12.5% polyacrylamide gel electrophoretic separation with a subsequent electrotransfer (PAGE-WB) was developed and the evaluation of 121 patients with suspected MS was carried out simultaneously with the IEF. MS-related PAGE-WB patterns were the increase in the concentration of Kappa monomers or Lambda dimers in CSF compared to serum. This method had a very high significance of association with the IEF (p<0.0001) with 95% sensitivity, 90% specificity, 83% PPV and 97% NPV. Intrathecal synthesis of FLC was evidenced by the increased intensity of the Kappa monomers and/or Lambda dimers observed in CSF. The PAGE-WB technique for FLC proved to be an alternative method to detect intrathecal synthesis in patients with suspected MS.


Resumo O método de referência para o estudo bioquímico da esclerose múltipla (EM) é a focalização isoelétrica (IEE) e a avaliação de cadeias leves livres (CLL) poderiam fornecer informações adicionais de relevância. Assim, propõe-se avaliar a presença das CLL e a aplicabilidade dos estados de polimerização no estudo de EM. Foi desenvolvido um método que consiste na separação eletroforética em gel de poliacrilamida a 12,5% com posterior eletrotranferência (PAGE-WB) e a avaliação de 121 pacientes com suspeita de EM foi realizada paralelamente à IEE. Os padrões de PAGE-WB relacionados com a EM foram o aumento na concentração de monômeros Kappa ou dímeros Lambda em líquido cefalorraquidiano (LCR) em comparação com o soro. Este método teve uma associação de significância muito alta com o IEE (p<0,0001) com sensibilidade de 95%, especificidade de 90%, VPP 83% e VPN 97%. A síntese intratecal de CLL foi evidenciada pelo aumento de intensidade do monômero Kappa e/ou dímero Lambda observado em LCR. A técnica PAGE-WB para CLL mostrou-se um método alternativo para detectar a síntese intratecal em pacientes com suspeita de EM.


Asunto(s)
Bandas Oligoclonales , Esclerosis Múltiple , Estándares de Referencia , Derivación y Consulta , Asociación , Líquido Cefalorraquídeo , Sensibilidad y Especificidad , Suero , Polimerizacion , Focalización Isoeléctrica
9.
Front Radiol ; 2: 930666, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-37492668

RESUMEN

Quantitative magnetic resonance imaging (qMRI) can increase the specificity and sensitivity of conventional weighted MRI to underlying pathology by comparing meaningful physical or chemical parameters, measured in physical units, with normative values acquired in a healthy population. This study focuses on multi-echo T2 relaxometry, a qMRI technique that probes the complex tissue microstructure by differentiating compartment-specific T2 relaxation times. However, estimation methods are still limited by their sensitivity to the underlying noise. Moreover, estimating the model's parameters is challenging because the resulting inverse problem is ill-posed, requiring advanced numerical regularization techniques. As a result, the estimates from distinct regularization strategies are different. In this work, we aimed to investigate the variability and reproducibility of different techniques for estimating the transverse relaxation time of the intra- and extra-cellular space (T2IE) in gray (GM) and white matter (WM) tissue in a clinical setting, using a multi-site, multi-session, and multi-run T2 relaxometry dataset. To this end, we evaluated three different techniques for estimating the T2 spectra (two regularized non-negative least squares methods and a machine learning approach). Two independent analyses were performed to study the effect of using raw and denoised data. For both the GM and WM regions, and the raw and denoised data, our results suggest that the principal source of variance is the inter-subject variability, showing a higher coefficient of variation (CoV) than those estimated for the inter-site, inter-session, and inter-run, respectively. For all reconstruction methods studied, the CoV ranged between 0.32 and 1.64%. Interestingly, the inter-session variability was close to the inter-scanner variability with no statistical differences, suggesting that T2IE is a robust parameter that could be employed in multi-site neuroimaging studies. Furthermore, the three tested methods showed consistent results and similar intra-class correlation (ICC), with values superior to 0.7 for most regions. Results from raw data were slightly more reproducible than those from denoised data. The regularized non-negative least squares method based on the L-curve technique produced the best results, with ICC values ranging from 0.72 to 0.92.

10.
Neuroimage ; 248: 118718, 2022 03.
Artículo en Inglés | MEDLINE | ID: mdl-34767939

RESUMEN

Noninvasive estimation of axon diameter with diffusion MRI holds the potential to investigate the dynamic properties of the brain network and pathology of neurodegenerative diseases. Recent studies use powder averaging to account for complex white matter architectures, but these have not been validated for real axonal geometries from regions that contain fibre crossings. Here, we present 120-304µm long segmented axons from X-ray nano-holotomography volumes of a splenium and crossing fibre region of a vervet monkey brain. We show that the axons in the complex crossing fibre region, which contains callosal, association, and corticospinal connections, exhibit a wider diameter distribution than those of the splenium region. To accurately estimate the axon diameter in these regions, therefore, sensitivity to a wide range of diameters is required. We demonstrate how the q-value, b-value, signal-to-noise ratio and the assumed intra-axonal parallel diffusivity influence the range of measurable diameters with powder average approaches. Furthermore, we show how Gaussian distributed noise results in a wider range of measurable diameter at high b-values than Rician distributed noise, even at high signal-to-noise ratios of 100. The number of gradient directions is also shown to impose a lower bound on measurable diameter. Our results indicate that axon diameter estimation can be performed with only few b-shells, and that additional shells do not improve the accuracy of the estimate. For strong gradients available on human Connectom and preclinical scanners, Monte Carlo simulations of diffusion confirm that powder averaging techniques succeed in providing accurate estimates of axon diameter across a range of diameters, sequence parameters and diffusion times, even in complex white matter architectures. At relatively low b-values, the diameter estimate becomes sensitive to axonal microdispersion and the intra-axonal parallel diffusivity shows time dependency at both in vivo and ex vivo intrinsic diffusivities.


Asunto(s)
Axones/ultraestructura , Imagen de Difusión por Resonancia Magnética/métodos , Imagenología Tridimensional , Animales , Chlorocebus aethiops , Método de Montecarlo , Distribución Normal , Relación Señal-Ruido
11.
NMR Biomed ; 35(7): e4668, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-34936147

RESUMEN

Long acquisition times preclude the application of multiecho spin echo (MESE) sequences for myelin water fraction (MWF) mapping in daily clinical practice. In search of alternative methods, previous studies of interest explored the biophysical modeling of MWF from measurements of different tissue properties that can be obtained in scan times shorter than those required for the MESE. In this work, a novel data-driven estimation of MWF maps from fast relaxometry measurements is proposed and investigated. T1 and T2 relaxometry maps were acquired in a cohort of 20 healthy subjects along with a conventional MESE sequence. Whole-brain quantitative mapping was achieved with a fast protocol in 6 min 24 s. Reference MWF maps were derived from the MESE sequence (TA = 11 min 17 s) and their data-driven estimation from relaxometry measurements was investigated using three different modeling strategies: two general linear models (GLMs) with linear and quadratic regressors, respectively; a random forest regression model; and two deep neural network architectures, a U-Net and a conditional generative adversarial network (cGAN). Models were validated using a 10-fold crossvalidation. The resulting maps were visually and quantitatively compared by computing the root mean squared error (RMSE) between the estimated and reference MWF maps, the intraclass correlation coefficients (ICCs) between corresponding MWF values in different brain regions, and by performing Bland-Altman analysis. Qualitatively, the estimated maps appear to generally provide a similar, yet more blurred MWF contrast in comparison with the reference, with the cGAN model best capturing MWF variabilities in small structures. By estimating the average adjusted coefficient of determination of the GLM with quadratic regressors, we showed that 87% of the variability in the MWF values can be explained by relaxation times alone. Further quantitative analysis showed an average RMSE smaller than 0.1% for all methods. The ICC was greater than 0.81 for all methods, and the bias smaller than 2.19%. It was concluded that this work confirms the notion that relaxometry parameters contain a large part of the information on myelin water and that MWF maps can be generated from T1 /T2 data with minimal error. Among the investigated modeling approaches, the cGAN provided maps with the best trade-off between accuracy and blurriness. Fast relaxometry, like the 6 min 24 s whole-brain protocol used in this work in conjunction with machine learning, may thus have the potential to replace time-consuming MESE acquisitions.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Vaina de Mielina , Encéfalo/diagnóstico por imagen , Mapeo Encefálico , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Imagen por Resonancia Magnética/métodos , Vaina de Mielina/química , Agua/química
12.
Magn Reson Imaging ; 86: 118-134, 2022 02.
Artículo en Inglés | MEDLINE | ID: mdl-34856330

RESUMEN

In magnetic resonance imaging, the application of a strong diffusion weighting suppresses the signal contributions from the less diffusion-restricted constituents of the brain's white matter, thus enabling the estimation of the transverse relaxation time T2 that arises from the more diffusion-restricted constituents such as the axons. However, the presence of cell nuclei and vacuoles can confound the estimation of the axonal T2, as diffusion within those structures is also restricted, causing the corresponding signal to survive the strong diffusion weighting. We devise an estimator of the axonal T2 based on the directional spherical variance of the strongly diffusion-weighted signal. The spherical variance T2 estimates are insensitive to the presence of isotropic contributions to the signal like those provided by cell nuclei and vacuoles. We show that with a strong diffusion weighting these estimates differ from those obtained using the directional spherical mean of the signal which contains both axonal and isotropically-restricted contributions. Our findings hint at the presence of an MRI-visible isotropically-restricted contribution to the signal in the white matter ex vivo fixed tissue (monkey) at 7T, and do not allow us to discard such a possibility also for in vivo human data collected with a clinical 3T system.


Asunto(s)
Imagen de Difusión por Resonancia Magnética , Sustancia Blanca , Axones , Encéfalo/diagnóstico por imagen , Imagen de Difusión por Resonancia Magnética/métodos , Imagen por Resonancia Magnética , Sustancia Blanca/diagnóstico por imagen
13.
Data Brief ; 38: 107429, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34632021

RESUMEN

The methodological development in the mapping of the brain structural connectome from diffusion-weighted magnetic resonance imaging (DW-MRI) has raised many hopes in the neuroscientific community. Indeed, the knowledge of the connections between different brain regions is fundamental to study brain anatomy and function. The reliability of the structural connectome is therefore of paramount importance. In the search for accuracy, researchers have given particular attention to linking white matter tractography methods - used for estimating the connectome - with information about the microstructure of the nervous tissue. The creation and validation of methods in this context were hampered by a lack of practical numerical phantoms. To achieve this, we created a numerical phantom that mimics complex anatomical fibre pathway trajectories while also accounting for microstructural features such as axonal diameter distribution, myelin presence, and variable packing densities. The substrate has a micrometric resolution and an unprecedented size of 1 cubic millimetre to mimic an image acquisition matrix of 40 × 40 × 40 voxels. DW-MRI images were obtained from Monte Carlo simulations of spin dynamics to enable the validation of quantitative tractography. The phantom is composed of 12,196 synthetic tubular fibres with diameters ranging from 1.4 µm to 4.2 µm, interconnecting sixteen regions of interest. The simulated images capture the microscopic properties of the tissue (e.g. fibre diameter, water diffusing within and around fibres, free water compartment), while also having desirable macroscopic properties resembling the anatomy, such as the smoothness of the fibre trajectories. While previous phantoms were used to validate either tractography or microstructure, this phantom can enable a better assessment of the connectome estimation's reliability on the one side, and its adherence to the actual microstructure of the nervous tissue on the other.

14.
Neuroimage ; 244: 118582, 2021 12 01.
Artículo en Inglés | MEDLINE | ID: mdl-34536538

RESUMEN

Multi-echo T2 magnetic resonance images contain information about the distribution of T2 relaxation times of compartmentalized water, from which we can estimate relevant brain tissue properties such as the myelin water fraction (MWF). Regularized non-negative least squares (NNLS) is the tool of choice for estimating non-parametric T2 spectra. However, the estimation is ill-conditioned, sensitive to noise, and highly affected by the employed regularization weight. The purpose of this study is threefold: first, we want to underline that the apparently innocuous use of two alternative parameterizations for solving the inverse problem, which we called the standard and alternative regularization forms, leads to different solutions; second, to assess the performance of both parameterizations; and third, to propose a new Bayesian regularized NNLS method (BayesReg). The performance of BayesReg was compared with that of two conventional approaches (L-curve and Chi-square (X2) fitting) using both regularization forms. We generated a large dataset of synthetic data, acquired in vivo human brain data in healthy participants for conducting a scan-rescan analysis, and correlated the myelin content derived from histology with the MWF estimated from ex vivo data. Results from synthetic data indicate that BayesReg provides accurate MWF estimates, comparable to those from L-curve and X2, and with better overall stability across a wider signal-to-noise range. Notably, we obtained superior results by using the alternative regularization form. The correlations reported in this study are higher than those reported in previous studies employing the same ex vivo and histological data. In human brain data, the estimated maps from L-curve and BayesReg were more reproducible. However, the T2 spectra produced by BayesReg were less affected by over-smoothing than those from L-curve. These findings suggest that BayesReg is a good alternative for estimating T2 distributions and MWF maps.


Asunto(s)
Encéfalo/diagnóstico por imagen , Imagen por Resonancia Magnética/métodos , Teorema de Bayes , Femenino , Técnicas Histológicas , Humanos , Análisis de los Mínimos Cuadrados , Masculino , Vaina de Mielina/metabolismo , Agua/metabolismo , Adulto Joven
15.
Neuroimage ; 243: 118502, 2021 11.
Artículo en Inglés | MEDLINE | ID: mdl-34433094

RESUMEN

White matter bundle segmentation using diffusion MRI fiber tractography has become the method of choice to identify white matter fiber pathways in vivo in human brains. However, like other analyses of complex data, there is considerable variability in segmentation protocols and techniques. This can result in different reconstructions of the same intended white matter pathways, which directly affects tractography results, quantification, and interpretation. In this study, we aim to evaluate and quantify the variability that arises from different protocols for bundle segmentation. Through an open call to users of fiber tractography, including anatomists, clinicians, and algorithm developers, 42 independent teams were given processed sets of human whole-brain streamlines and asked to segment 14 white matter fascicles on six subjects. In total, we received 57 different bundle segmentation protocols, which enabled detailed volume-based and streamline-based analyses of agreement and disagreement among protocols for each fiber pathway. Results show that even when given the exact same sets of underlying streamlines, the variability across protocols for bundle segmentation is greater than all other sources of variability in the virtual dissection process, including variability within protocols and variability across subjects. In order to foster the use of tractography bundle dissection in routine clinical settings, and as a fundamental analytical tool, future endeavors must aim to resolve and reduce this heterogeneity. Although external validation is needed to verify the anatomical accuracy of bundle dissections, reducing heterogeneity is a step towards reproducible research and may be achieved through the use of standard nomenclature and definitions of white matter bundles and well-chosen constraints and decisions in the dissection process.


Asunto(s)
Imagen de Difusión Tensora/métodos , Disección/métodos , Sustancia Blanca/diagnóstico por imagen , Algoritmos , Humanos , Procesamiento de Imagen Asistido por Computador/métodos , Vías Nerviosas/diagnóstico por imagen
16.
Med Image Anal ; 69: 101959, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-33581618

RESUMEN

Multi-component T2 relaxometry allows probing tissue microstructure by assessing compartment-specific T2 relaxation times and water fractions, including the myelin water fraction. Non-negative least squares (NNLS) with zero-order Tikhonov regularization is the conventional method for estimating smooth T2 distributions. Despite the improved estimation provided by this method compared to non-regularized NNLS, the solution is still sensitive to the underlying noise and the regularization weight. This is especially relevant for clinically achievable signal-to-noise ratios. In the literature of inverse problems, various well-established approaches to promote smooth solutions, including first-order and second-order Tikhonov regularization, and different criteria for estimating the regularization weight have been proposed, such as L-curve, Generalized Cross-Validation, and Chi-square residual fitting. However, quantitative comparisons between the available reconstruction methods for computing the T2 distribution, and between different approaches for selecting the optimal regularization weight, are lacking. In this study, we implemented and evaluated ten reconstruction algorithms, resulting from the individual combinations of three penalty terms with three criteria to estimate the regularization weight, plus non-regularized NNLS. Their performance was evaluated both in simulated data and real brain MRI data acquired from healthy volunteers through a scan-rescan repeatability analysis. Our findings demonstrate the need for regularization. As a result of this work, we provide a list of recommendations for selecting the optimal reconstruction algorithms based on the acquired data. Moreover, the implemented methods were packaged in a freely distributed toolbox to promote reproducible research, and to facilitate further research and the use of this promising quantitative technique in clinical practice.


Asunto(s)
Vaina de Mielina , Agua , Algoritmos , Humanos , Imagen por Resonancia Magnética , Relación Señal-Ruido
17.
Med Image Anal ; 69: 101940, 2021 04.
Artículo en Inglés | MEDLINE | ID: mdl-33422828

RESUMEN

Recovering the T2 distribution from multi-echo T2 magnetic resonance (MR) signals is challenging but has high potential as it provides biomarkers characterizing the tissue micro-structure, such as the myelin water fraction (MWF). In this work, we propose to combine machine learning and aspects of parametric (fitting from the MRI signal using biophysical models) and non-parametric (model-free fitting of the T2 distribution from the signal) approaches to T2 relaxometry in brain tissue by using a multi-layer perceptron (MLP) for the distribution reconstruction. For training our network, we construct an extensive synthetic dataset derived from biophysical models in order to constrain the outputs with a priori knowledge of in vivo distributions. The proposed approach, called Model-Informed Machine Learning (MIML), takes as input the MR signal and directly outputs the associated T2 distribution. We evaluate MIML in comparison to a Gaussian Mixture Fitting (parametric) and Regularized Non-Negative Least Squares algorithms (non-parametric) on synthetic data, an ex vivo scan, and high-resolution scans of healthy subjects and a subject with Multiple Sclerosis. In synthetic data, MIML provides more accurate and noise-robust distributions. In real data, MWF maps derived from MIML exhibit the greatest conformity to anatomical scans, have the highest correlation to a histological map of myelin volume, and the best unambiguous lesion visualization and localization, with superior contrast between lesions and normal appearing tissue. In whole-brain analysis, MIML is 22 to 4980 times faster than the non-parametric and parametric methods, respectively.


Asunto(s)
Imagen por Resonancia Magnética , Vaina de Mielina , Algoritmos , Encéfalo/diagnóstico por imagen , Humanos , Aprendizaje Automático
18.
Magn Reson Med ; 85(1): 209-222, 2021 01.
Artículo en Inglés | MEDLINE | ID: mdl-32720406

RESUMEN

PURPOSE: Although several MRI methods have been explored to achieve in vivo myelin quantification, imaging the whole brain in clinically acceptable times and sufficiently high resolution remains challenging. To address this problem, this work investigates the acceleration of multi-echo T2 acquisitions based on the multi-echo gradient and spin echo (GRASE) sequence using CAIPIRINHA undersampling and adapted k-space reordering patterns. METHODS: A prototype multi-echo GRASE sequence supporting CAIPIRINHA parallel imaging was implemented. Multi-echo T2 data were acquired from 12 volunteers using the implemented sequence (1.6 × 1.6 × 1.6 mm3 , 84 slices, acquisition time [TA] = 10:30 min) and a multi-echo spin echo (MESE) sequence as reference (1.6 × 1.6 × 3.2 mm3 , single-slice, TA = 5:41 min). Myelin water fraction (MWF) maps derived from both acquisitions were compared via correlation and Bland-Altman analyses. In addition, scan-rescan datasets were acquired to evaluate the repeatability of the derived maps. RESULTS: Resulting maps from the MESE and multi-echo GRASE sequences were found to be correlated (r = 0.83). The Bland-Altman analysis revealed a mean bias of -0.2% (P = .24) with the limits of agreement ranging from -3.7% to 3.3%. The Pearson's correlation coefficient among MWF values obtained from the scan-rescan datasets was found to be 0.95 and the mean bias equal to 0.11% (P = .32), indicating good repeatability of the retrieved maps. CONCLUSION: By combining a 3D multi-echo GRASE sequence with CAIPIRINHA sampling, whole-brain MWF maps were obtained in 10:30 min with 1.6 mm isotropic resolution. The good correlation with conventional MESE-based maps demonstrates that the implemented sequence may be a promising alternative to time-consuming MESE acquisitions.


Asunto(s)
Procesamiento de Imagen Asistido por Computador , Vaina de Mielina , Agua , Encéfalo/diagnóstico por imagen , Mapeo Encefálico , Humanos , Imagen por Resonancia Magnética
19.
Neuroimage ; 206: 116274, 2020 02 01.
Artículo en Inglés | MEDLINE | ID: mdl-31629826

RESUMEN

Phase correction (PC) is a preprocessing technique that exploits the phase of images acquired in Magnetic Resonance Imaging (MRI) to obtain real-valued images containing tissue contrast with additive Gaussian noise, as opposed to magnitude images which follow a non-Gaussian distribution, e.g. Rician. PC finds its natural application to diffusion-weighted images (DWIs) due to their inherent low signal-to-noise ratio and consequent non-Gaussianity that induces a signal overestimation bias that propagates to the calculated diffusion indices. PC effectiveness depends upon the quality of the phase estimation, which is often performed via a regularization procedure. We show that a suboptimal regularization can produce alterations of the true image contrast in the real-valued phase-corrected images. We propose adaptive phase correction (APC), a method where the phase is estimated by using MRI noise information to perform a complex-valued image regularization that accounts for the local variance of the noise. We show, on synthetic and acquired data, that APC leads to phase-corrected real-valued DWIs that present a reduced number of alterations and a reduced bias. The substantial absence of parameters for which human input is required favors a straightforward integration of APC in MRI processing pipelines.


Asunto(s)
Encéfalo/diagnóstico por imagen , Imagen de Difusión por Resonancia Magnética/métodos , Procesamiento de Imagen Asistido por Computador/métodos , Neuroimagen/métodos , Adulto , Artefactos , Simulación por Computador , Imagen de Difusión por Resonancia Magnética/normas , Humanos , Procesamiento de Imagen Asistido por Computador/normas , Neuroimagen/normas , Relación Señal-Ruido
20.
Acta bioquím. clín. latinoam ; 53(1): 8-8, mar. 2019.
Artículo en Español | LILACS-Express | LILACS | ID: biblio-1038089
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...